You are here

VA520 Calorimetric mass flow meter, CS-Instruments

Calorimetric flowmeter for compressed air and gases

• The VA520 comes with an integrated pipe with a choice of thread or flange connection. Pipe size 1/2 ... 2 ”
• Local display
• Accuracy ± 1.5% of measurement reading ± 0.3% of total range
(also available ± 1,0% of measured value ± 0,3% of full scale)
• Local display whose units can be freely set (m³ / h, m³ / min, l / min, l / s, ft / min, cfm, m / s, kg / h, kg / min, Nm³ / h, Nl / min )
• Fluids compressed air and other dry and clean gases (the meter can also be calibrated with the gas used in the application)
• Fluid temperature -30 ... 110 ° C
• Maximum press 50 bar
• RS485, Modbus RTU as standard and also M-bus on request
• Analog output 4-20mA
• Galvanically isolated pulse output